For noise, Chile has emission standards. For vibration, it does not. The Guía para la predicción y evaluación de impactos por ruido y vibración en el SEIA (guide for predicting and assessing noise and vibration impacts in the SEIA), published by the Servicio de Evaluación Ambiental (SEA, the Environmental Assessment Service), says so itself: there is no environmental regulation in Chile applicable to vibration as a pollutant. Even so, projects entering the Sistema de Evaluación de Impacto Ambiental (SEIA, the Environmental Impact Assessment System) that generate vibration must assess whether their impact is significant. The question is what yardstick to use.
The Regulation’s answer: reference standards
The SEIA Regulation (Decreto Supremo N°40/2012 of the Ministerio del Medio Ambiente, the Ministry of the Environment) fills the gap with reference standards. Its article 11 provides that the standards in force in fourteen States are to be used: Germany, Argentina, Australia, Brazil, Canada, Spain, Mexico, the United States, New Zealand, the Netherlands, Italy, Japan, Sweden and Switzerland.
Choosing is not enough. Priority must be given to the State with environmental conditions most similar to the national or local situation, the project owner has to justify that choice reasonably, and it must attach a complete and current copy of the standard it used. If none of those countries has a standard for the case, the SEA Guide says to use reference values, for example those recommended by international organisations.
What is assessed: two protection objectives
The SEA Guide develops the vibration assessment for two protection objectives:
- Health of the population. Human receptors are identified and the vibration level at each one is estimated, to be compared with a reference standard.
- Cultural heritage. For heritage buildings and structures, the peak particle velocity (PPV) and the vibration velocity level (Lv) to which they will be exposed under the worst-case condition are considered and compared with a reference standard.
Which standards the Guide recommends
The Guide does not impose a standard: it recommends some in common use, by type of source. If the project owner uses another one, it must provide a technical justification and spell out its advantages over the recommended ones.
- Construction machinery: BS 5228-2 (United Kingdom), and the guides of the Federal Transit Administration (FTA) and the California Department of Transportation (Caltrans), both from the United States.
- Transit: FTA and Caltrans.
- Blasting: BS 6472-2 and BS 7385-2 (United Kingdom), USBM RI 8507 (United States) and AS 2187.2 (Australia).
- Machinery with continuous vibration: ANSI S3.29.
- Any type of source: DIN 4150-2, for people, and DIN 4150-3, for structures (Germany).
Blasting: a different source, a different standard
Blasting is not assessed like machinery or traffic. Its vibration is impulsive and depends on factors such as the explosive charge, the detonation method and the type of ground, so the SEA Guide says to estimate it case by case.
One of the reference standards the Guide recommends for blasting is the Australian AS 2187.2, “Explosives — Storage and use. Part 2: Use of explosives” (Standards Australia, 2006 edition, current). Its Appendix J, which is informative, deals with ground vibration and airblast overpressure, and separates two questions: comfort for people and damage to structures.
For people, AS 2187.2 gives peak particle velocity limits that some authorities have adopted. At sensitive sites, such as houses, schools or theatres, the value is a maximum of 10 mm/s if the operation lasts less than twelve months or involves fewer than twenty blasts. If it lasts longer, it is 5 mm/s for 95% of the year’s blasts, with a maximum of 10 mm/s. In both cases a higher value may be agreed with the occupier.
For damage to structures, it recommends frequency-dependent criteria taken from BS 7385-2 (United Kingdom) and USBM RI 8507 (United States). Vibration is measured in three perpendicular directions.
Two warnings from the standard itself: Appendix J is informative and does not replace the legal requirements of each jurisdiction, and its tables do not cover high-rise buildings, buildings with long-span floors, specialist structures such as reservoirs, dams and hospitals, or buildings housing scientific equipment sensitive to vibration, which require special consideration.
These values are not Chilean limits: they are references that a project owner may adopt if it justifies the choice and attaches the standard. Blasting is common in mining projects; for that sector, see our note on noise and vibration in mining projects.
The FTA, in three levels of analysis
For transit, the FTA is one of the most widely used references in Chile, and the SEA Guide itself recommends it. Its manual organises the assessment in three levels:
- Identification procedure. It defines the study area. If there are no vibration-sensitive land uses within the identification distances, no further analysis is required.
- General analysis. It projects the vibration level at each receptor from a base curve, with adjustments for the source, the propagation path and the receptor.
- Detailed analysis. It incorporates field measurements and projects in one-third octave bands.
The level that applies depends on the type and scale of the project. In a railway project approved in the SEIA in 2023, the general analysis showed the limits being exceeded at two receptors and a detailed analysis was needed. With it, both complied and no mitigation measures were required. In our team’s experience, it is common for railway projects to go up to that level.
In an upcoming note we look at when the general analysis is enough and what the detailed one requires.
What to define from the start
- Which reference standard will be used, why it is the most similar to the local situation and how the choice will be justified.
- A complete and current copy of that standard, which must be attached to the study.
- Which protection objectives are present in the surroundings — people, cultural heritage or both — and where the receptors are.
- If there is blasting, that the assessment follows a different path, with its own standards.
For the most frequent SEA observations on noise and vibration, see our note “Noise and Vibration in the SEIA: How to Avoid SEA Observations”.
If your project will enter the SEIA and has vibration sources, see our acoustic and vibration impact studies for the SEIA. Would you rather talk it through? Book a 20-minute call: we will carry out a free preliminary diagnosis and send you a free technical proposal within 1 to 5 working days.

He leads Acústica Austral’s environmental noise and vibration studies for the SEIA across energy, port and infrastructure projects, and has contributed to reference work for Chile’s Ministry of the Environment.
Meet the team →Free resources for your project
Guide to the D.S. N°14/2024 and the acoustic checklist for entering the SEIA, in PDF. We email them to you.