In August we explained what the assessment of noise and shadow flicker at wind farms currently requires in Chile: the Environmental Assessment Service (SEA) recommends the German technical guideline as its reference, with a maximum of 30 hours per year and 30 minutes per day in the worst-case astronomical scenario, and 8 hours per year in the real scenario. This article goes one step further: how to build the calculation so that it holds up during the assessment, and what to do when a receptor exceeds those values.
The reference is the SEA technical document Criterio de evaluación en el SEIA: efecto sombra intermitente en parques eólicos (SEIA assessment criterion: shadow flicker at wind farms, June 2021). It starts from a simple fact: Chile has no standard for this effect, so it is assessed as a risk to public health (Article 11(a) of Law No. 19,300), using international reference standards.
Two scenarios, two ways of looking at the receptor
The SEA criterion requires both scenarios of the German guideline to be presented, and each treats the receptor differently:
- Worst case: greenhouse mode. Sunshine all day, clear skies, the rotor perpendicular to the sun’s rays and the wind farm in operation. The dwelling is modelled as a translucent element: shadow can «enter» from any direction. It is deliberately conservative.
- Real case: the dwelling as it is. Site weather conditions are included (sunshine hours and cloud cover, from nearby weather stations or atmospheric models such as WRF), together with the layout and orientation of the dwellings, topography, existing natural barriers and turbine orientation according to the prevailing wind.
In both cases the receptor is assessed at a reference height of 2 m above ground. Sun positions below 3° above the horizon are not considered, and the study area extends to the distance at which a rotor blade still covers 20% of the solar disc.
Where the result is decided
Two models with the same turbines can give very different results depending on the assumptions. The ones that matter most:
- Window size and orientation. The SEA criterion asks for the receptor’s orientation, light openings, window dimensions and inclination «for the real case, as applicable», but does not set a size. Neither does the German guideline. In practice a 1 × 1 m window is used, the default in the most widely used software. If a developer adopts a different size, it is best justified with the actual dwelling. In Germany, a 1 × 1 m window facing the nearest turbine is usually assumed. Once the wind farm is in operation and automatic shutdown of that turbine is programmed, the actual dimensions of each window are used.
- Obstacles. The criterion allows natural barriers to be considered in the real case. The German guideline specifies that they must be permanent and opaque. A row of deciduous trees, or a forestry plantation due for harvest, will hardly meet that requirement.
- Operation. The model assumes enough wind at hub height for the rotor to turn. The assumed operating time and cut-in wind speed must be stated.
- Neighbouring wind farms. A receptor may receive shadow from another project’s turbines. Separating the project’s contribution from that of third parties, rather than leaving it out, avoids the omission being read as hiding a cumulative effect.
What has to be submitted
According to the SEA criterion, the study must include:
- The turbine data sheet: hub height, rotor diameter and blade width.
- A clear description of the receptors within the area of influence: dwellings, but also bedrooms in hotels and hospitals, classrooms and offices. Terraces and balconies are protected from 6:00 to 22:00.
- A table per receptor with daily shadow duration, to a precision of 1 minute per day, and annual duration in hours.
- A map with shadow isolines, especially the 30-hour-per-year isoline.
- The software calculation report with all assumptions: minimum sun elevation, time step, monthly probability of sunshine, operating time, cut-in wind speed, contour lines, obstacles, eye height and grid resolution.
- A KMZ file with all the information, in UTM coordinates.
If a receptor exceeds the values
The SEA criterion distinguishes two cases:
- Case 1. The developer includes an automatic temporary shutdown system (the «shadow detection system», whose name varies by supplier) as part of the project design, with its up-to-date data sheet. In that case the SEA considers that shadow flicker does not cause significant impacts. The system uses radiation or light sensors and is set to the real-scenario value: 8 hours per year.
- Case 2. The developer does not include such a system. Whether the impact is significant must then be assessed under Article 5 of the SEIA Regulation and, if it is, measures must be proposed.
One point worth keeping in mind from the design stage: the SEA does not accept natural or artificial barriers as a measure to address a significant impact, because they replace flickering shadow with permanent shade over the dwelling.
So when the model shows exceedances, the useful conversation is not how far the result can be lowered through assumptions, but which turbines will have shutdown, for which receptors and at what times. That decision belongs to the developer, and the study should give them the information to make it.
How we do it
We model shadow flicker with windPRO, covering both scenarios of the SEA criterion, with tables per receptor, isolines and KMZ, and we respond to the SEA’s observations on this effect during the assessment.