A discrete noise measurement tells you how loud a source is at a given moment, on the day it was measured. Often that is enough, when the source is continuous and its emission does not vary. But some sources do not sound the same at every hour, some receptors only have a problem at night, and one standard requires, for certain sources, relating noise to another variable over many days. In those cases a different tool is needed: a continuous noise monitoring station.
What a remote monitoring station is
It is a sound level meter installed at the receptor point that measures without interruption for days, weeks or months, with no operator beside it. Besides the instrument, the station has a weatherproof enclosure, a microphone protected against wind and rain, an autonomous power supply and memory to store the records. Something essential in an unattended noise measurement is that it records audio, so that you can listen and confirm that the measured noise levels are related to the source you want to assess.
What sets it apart is not the equipment but the result: instead of one value per point, it delivers a time series.
What data it delivers
Depending on how it is configured, a station records:
- Levels per interval: the equivalent continuous level (Leq), percentiles such as L90 and the maximum level, over fixed intervals of minutes.
- Frequency spectrum: to identify which source dominates at each moment.
- Audio: recordings that let you listen afterwards to what happened in an interval and separate the source from incidental noise, such as a dog, a vehicle or rain.
- Context variables: wind and rain on site and, where relevant, the operating data of the source over the same period.
The value lies in cross-referencing those series. A ten-minute interval over fourteen days means 2,016 records at a single point, as we explained in our article on wind farm noise data post-processing. What defines the result is what is discarded and why, not the average.
When it beats a discrete measurement
A discrete measurement is usually enough when the source operates steadily, when its schedule is well known and when the aim is to verify compliance under defined conditions. For general fixed sources, Decreto Supremo N°14/2024 (Supreme Decree 14/2024) of the MMA (Ministerio del Medio Ambiente, Ministry of the Environment) assesses an outdoor 15-minute Leq (art. 16).
Continuous monitoring is the better choice in these cases:
- Wind farms. D.S. N°14/2024 obtains a wind farm’s emission level by correlating 10-minute L90 values with wind speed at hub height, through a regression curve with R² ≥ 0.6 (art. 17). That curve can only be built from many records covering different wind speeds, and that requires continuous measurement.
- Sources that change with operation. Plants that vary their load, equipment that runs in shifts or works that change from one day to the next. A discrete measurement may fall at the best or the worst moment and represent neither.
- Complaints that arise at night or intermittently. If the community complains about a noise that is not present when someone goes to measure, monitoring with audio shows whether the event exists, when it happens and which source it comes from.
- Follow-up of a control measure. Measuring before and after installing a barrier or a silencer, under the same conditions, to know whether it worked.
- When the RCA requires it. If the project’s RCA (Resolución de Calificación Ambiental, environmental approval) sets out noise monitoring, the campaign must be designed to answer exactly what it asks.
What to define before installing
A poorly designed long-term monitoring campaign produces a lot of useless data. Before installing, it is worth defining:
- The question: regulatory compliance, response to a complaint or follow-up of a measure. Each calls for a different point, duration and processing.
- The duration: for wind farms we recommend measuring for at least one month per point. For other projects it varies and depends on how the source changes: it may be at least 24 hours.
- The point: at the receptor or at an intermediate position, with access, security and the owner’s permission.
- Synchronisation: the station’s clock must match that of the wind and source operating data. Without it, no correlation is possible.
- Exclusion criteria: rain, wind on the microphone and incidental noise, defined before looking at the results.
A point of context: the measurement protocols of D.S. N°14/2024, to be issued by the SMA (Superintendencia del Medio Ambiente, Environmental Superintendency) under art. 22, are what will set the technical criteria for processing wind farm data. We reviewed what is known about them in our article on the measurement protocols. Meanwhile, D.S. N°38/11 still applies during the transition: D.S. N°14/2024 applies from 27 August 2027 to projects entering the SEIA (Sistema de Evaluación de Impacto Ambiental, Environmental Impact Assessment System) after its publication, and from 27 August 2028 to all other fixed sources. We explain it in our article on its entry into force.
How we do it
We have continuous noise monitoring stations with Class 1 instrumentation and we design the whole campaign: location of the points, configuration, synchronisation with the source data, processing and calculation report. We have carried out continuous measurements at wind farms for the Ministry of the Environment, in the acoustic characterisation of six wind farms (2017-2018) and in the measurement protocol for two operating wind farms (2025). In addition, in the project «Actualización y evaluación de los niveles de ruido en la comuna de Coronel» (Update and assessment of noise levels in the municipality of Coronel, 2023-2025), we used two online continuous noise monitoring stations for twelve months.
If your project needs noise monitoring, see our acoustic optimisation of wind farms service or our environmental noise control service.
Are you assessing whether your project needs continuous monitoring? Book a 20-minute call: we will carry out a free preliminary diagnosis and send you a free technical proposal within 1 to 5 working days.

He leads Acústica Austral’s environmental noise and vibration studies for the SEIA across energy, port and infrastructure projects, and has contributed to reference work for Chile’s Ministry of the Environment.
Meet the team →Free resources for your project
Guide to the D.S. N°14/2024 and the acoustic checklist for entering the SEIA, in PDF. We email them to you.