A site exceeds the noise limit at a neighbouring home. The first question is usually which product to install. The question that organises everything else is a different one: by how many decibels does the level have to come down, and by what path does the noise reach the receptor?

First, how much has to come down

The difference between the level reaching the receptor and the limit that applies to it is the gap. It is measured or modelled in dB(A), and it is worth looking at it by octave band as well, because each solution attenuates differently depending on frequency.

The limit depends on the standard and the zone. D.S. N°38/11 (MMA) continues to apply during the transition. D.S. N°14/2024 (MMA) enters into force on 27 August 2027 for projects entering the Environmental Impact Assessment System (SEIA) from its publication, and on 27 August 2028 for the rest of fixed sources. Which period applies to you is explained in our note on the entry into force of D.S. N°14/2024.

Then, where to act

There are three places: the source, the path between the source and the receptor, and the receptor. As an engineering criterion, it is best to start at the source, because that is where the noise has not yet spread in all directions. Acting at the receptor, for example with active noise control, is usually the last resort.

Which measure suits each source

The table summarises four frequent cases and what the technical data sheets of the company Silentium say (editions from 2015 to 2017, consulted on 18 and 19 October 2026). The figures are the manufacturer’s, not the results of any particular project.

Source Typical measure Data sheet figure
Exhaust of engines and generator sets Exhaust silencer, selected according to the engine’s exhaust gas flow Four lines: Industrial 15–20 dB(A), Residential 20–25, Critical 25–35 and Hospital 35–45.
Ventilation and air extraction from machine rooms and chimneys ADR-M splitter-type attenuator Insertion loss curves by frequency and back-pressure curves by length and face velocity. It gives no single figure.
Access to machine or generator rooms PA-900 acoustic door Rw 35. Transmission loss of 18 dB at 125 Hz and 40 dB at 4000 Hz. Tested at IDIEM to NCh 2786 Of2003 and ISO 717-1:1996, according to the data sheet.
Equipment or loading docks facing homes Barrier with PAC-A66 acoustic insulating panels Transmission loss of 22 dB at 125 Hz and 52 dB at 4000 Hz; STC 39. Tested at Riverbank Acoustical Laboratories (ASTM E90-09), according to the data sheet. Note: the transmission loss belongs to the panel; a barrier works through acoustic shadow, and what drops at the receptor depends on the distance between the source and the barrier and on the barrier’s height.

Three common mistakes

  1. Confusing the insulation of the material with the effect of the solution. A barrier’s transmission loss describes the material. What drops at the receptor depends on the height, the length, the distance and the position relative to the source.
  2. Looking only at the overall value. In the data sheets in the table, the loss at 125 Hz is less than half that of the high bands: 18 dB versus 40 dB for the door, 22 dB versus 52 dB for the panel. If the source concentrates its energy at low frequencies, you have to check band by band. Low frequency is a common problem, because those noise waves are harder to attenuate.
  3. Leaving a weak point. In general, with acoustic insulation, a chain is only as strong as its weakest link. An Rw 35 door on a cabin, container or room solves nothing if the ventilation system has no noise attenuation (all the noise would escape through it). In addition, every element adds pressure loss: the ADR-M data sheet includes back-pressure curves and silencers are selected according to the engine’s exhaust gas flow.

After installation, we measure

A measure is considered good when the level is measured again at the receptor and the gap has closed. We carry out that post-installation verification. It is an engineering verification: it has no legal validity before the Superintendencia del Medio Ambiente (SMA, the Environmental Superintendency); for that, a report from an Entidad Técnica de Fiscalización Ambiental (ETFA, an accredited environmental inspection body) is required.

How we do it

We carry out the environmental noise control engineering study: we measure or model the gap, define where to act and specify the measure. We are distributors of Silentium in the southern macrozone of Chile, and we say so up front: if the chosen measure is one of its solutions, we can supply it. The product comes after the study, not before.

The solutions in this note are on our pages for exhaust silencers, noise attenuators, acoustic doors and acoustic panels and barriers.

Does your site exceed a limit? Book a 20-minute call: we will carry out a free preliminary diagnosis and send you a free technical proposal within 1 to 5 working days.

Nicolás Bastián Monarca
About the author
Nicolás Bastián Monarca
Head of Engineering · Acoustic Civil Engineer · MSc in Acoustics and Vibration

He leads Acústica Austral’s environmental noise and vibration studies for the SEIA across energy, port and infrastructure projects, and has contributed to reference work for Chile’s Ministry of the Environment.