Featured project

Noise Level Assessment in Coronel

Acoustic camera and tripod-mounted sound level meter beside a truck route in Coronel

At a glance

Client
Ministry of the Environment
Location
Coronel, Biobío Region
Years
2015
Project type
Study for the regulator · Environmental and Social Recovery Program (PRAS)
Challenge
Noise diagnosis for the Environmental and Social Recovery Program (PRAS) of Coronel.
Result
Some 15,700 people above 55 dBA at night and 25.5% of educational facilities above 65 dBA during the day
Scale
54.9 km² assessed~80 noise sources catalogued53 measurement points6 project phases

Context

A study carried out in 2015 for the Undersecretariat of the Environment (MMA), under the Environmental and Social Recovery Program (PRAS) for the commune of Coronel, Biobío Region.

What we did

Structured in six (6) phases over an urban area of 54.9 km², it included a catalogue of around 80 noise sources, a citizen-participation process, and measurement campaigns for industrial sources, road traffic (53 measurement points) and rail traffic. This information was used to build noise maps by source type and overall, for the daytime and nighttime periods.

Result

The results revealed a significant impact: at night, around 15,700 people were potentially exposed to levels above 55 dBA, and 25.5% of educational facilities exceeded the 65 dBA daytime criterion. The study proposed control measures and drew conclusions on the gaps in the noise regulatory system.

Documentation

Executive summary of the study produced for the Chilean Ministry of the Environment · 2015. Public-access document: the button downloads the executive summary (PDF, 1.1 MB) hosted by Acústica Austral, because the original file is no longer available from the ministry’s catalogue. Official record in the MMA catalogue.

View documentation

Share on LinkedIn